Thermogroup Econoboard insulation boards for under tile heating
Econoboard is the Thermogroup insulation board that goes under an electric underfloor heating mat. Heat spreads in every direction until it meets a layer of thermal resistance, and the board is that layer: it sits between the substrate and the heating mat, so the heat travels up into the tiles instead of down into the slab or the subfloor. The boards come coated or uncoated, in 6mm and 10mm thicknesses, and each is 1.2m by 0.6m.
People search for it as Econoboard, underfloor heating boards, under tile insulation, thermal flooring insulation and 6mm thermal insulation board. This page explains the four packs, which one suits which floor, how the boards are fixed and how many to buy.
What an Econoboard is
The core of every Econoboard is extruded polystyrene, a closed cell foam that is light and does not soak up water. The coated boards add a fibre reinforced cement coating on both faces, which makes the board stiffer and gives it lateral stability on a timber floor. The uncoated boards are the bare foam, made for a concrete substrate that is already stable.
| Property | Value |
|---|---|
| Board size | 1.2m by 0.6m, which is 0.72 square metres a board |
| Thermal conductivity | 0.033 W/mK |
| Compressive strength | 300 kPa |
| Water absorption | 0.6 by volume |
| Foam core density | Made to 36 kg per cubic metre |
| Working temperature range | Minus 50 to plus 75 degrees Celsius |
The boards cut with a sharp blade or a wood saw, so no special tools are needed. They are rot proof and moisture resistant, which is why they suit a bathroom, a laundry or any wet room.
The four packs
| Pack | Thickness | Boards in the pack | Area | R value |
|---|---|---|---|---|
| Coated, 6mm | 6mm | 8 | 5.76 square metres | 0.15 m²K/W |
| Coated, 10mm | 10mm | 6 | 4.32 square metres | 0.27 m²K/W |
| Uncoated, 6mm | 6mm | 20 | 14.4 square metres | 0.18 m²K/W |
| Uncoated, 10mm | 10mm | 10 | 7.2 square metres | 0.30 m²K/W |
The R value is the board's resistance to heat flow, so a higher number slows downward heat loss more. The 10mm boards resist heat flow more than the 6mm, and the uncoated 6mm board rates a little above the coated 6mm because it has no cement layer. The thicker board adds 4mm to the floor height, so check the door clearance and the transition to the next room before you choose it.
Coated or uncoated
| Your floor | Use | Why |
|---|---|---|
| Timber subfloor | Coated only | It screws down easily and adds lateral stability to the subfloor |
| Concrete slab, dry room | Coated or uncoated | Both bed into tile adhesive on concrete |
| Bathroom, laundry or wet room | Coated | Uncoated is not recommended where a waterproofing layer goes directly over the insulation |
| Waterproofed floor | Coated, glued with a full bed of flexible adhesive | Screws and washers would break the waterproofing |
The simple rule is this: use coated boards on timber and in wet rooms, and use either type on a dry concrete slab. The uncoated board does not provide lateral stability, so it is not suitable for a timber floor.
How the boards are fixed
On a timber substrate, the coated boards are screwed down with fixing screws and washers at 300mm centres. That is about 10 fixings per board, in the middle as well as around the edge, which maximises the strength and the stability of the floor. As an alternative, coated boards can be glued to the timber with a full bed of flexible cement based tile adhesive.
On a concrete substrate, both coated and uncoated boards are glued down with a full bed of flexible cement based tile adhesive. Mix the adhesive to the adhesive manufacturer's powder to water ratio, which is wetter than usual because the boards take up some moisture. Spread enough adhesive for one board at a time with a notched trowel so it does not skin over, then press the board in and squeeze out any air pockets.
Lay the boards in an offset brick pattern, with the joints staggered, on a substrate that is secure, clean and free of dust and loose particles. Make every board as flush with its neighbour as possible, and tape the seams with reinforcing tape for a firmer finish.
Fixing accessories
| Part | What it is | How much |
|---|---|---|
| Reinforcing tape | 100mm wide, in a 25m roll | Allow 2m of tape per board |
| Fixing washers and screws | 32mm washers, in a pack of 100 | About 10 per board on timber |
| Zinc fixing washers | 35mm washers, in a pack of 100 | For screw fixing where a larger washer is wanted |
Wet rooms and waterproofing
For a bathroom or a wet room, choose the coated board. It is the board made for use under a waterproofing layer. Where the boards are laid over a waterproofed substrate, glue them with a full bed of flexible cement based tile adhesive, because driving screws through the waterproofing will compromise it. The boards go under the heating, and the tile adhesive and tiles go over it.
Plan the layers from the bottom up: the substrate, the adhesive, the Econoboard, a layer of adhesive, the heating mat, more adhesive and the tiles. The guide shows this build-up for a timber floor, a coated board on concrete and an uncoated board on concrete. See Thermogroup underfloor heating kits for the heating mats and underfloor heating for the wider range.
Why insulate under the heating
A solid concrete floor or screed absorbs cold and damp from below. Without a barrier, a heating mat on a slab spends part of its output warming the concrete, and the room heats slowly. A board between the slab and the mat stops that downward loss, so the mat warms the tile surface sooner and spends less time running. On a timber floor the same board keeps the heat out of the joists and the space below, and the coated version stiffens the floor under the tiles.
Insulation is optional, and the heating works without it. The board earns its place on a cold slab, over an unheated crawl space, or in a room that is heated for long periods, where the running time saved is largest.
Laying the boards step by step
- Measure the floor and work out the number of boards and the accessories.
- Check that the substrate is secure and free from dust, debris and loose particles.
- Cut the boards to the room layout with a sharp blade or a wood saw, and take care with the sharp tool.
- Set the cut boards out on the floor in an offset brick pattern before fixing any of them.
- On timber, fix the coated boards with screws and washers at 300mm centres. On concrete, spread flexible adhesive with a notched trowel one board at a time and press each board in.
- Check that the boards are flush, and tape the seams with reinforcing tape.
- Lay the heating mat over the boards, and tile over it with flexible tile adhesive.
A pack of 100 washers covers about 10 boards on a timber floor, because each board takes about 10 fixings. Order the washer pack with the boards, because the screws and washers are not in the board pack.
What not to do
- Do not lay the board on top of the underfloor heating. It goes underneath, between the substrate and the mat.
- Do not screw into water pipes or electrical cables. Check the subfloor before the fixings go in.
- Do not use uncoated board on timber, or under a waterproofing layer.
- Do not leave the joins uneven. Keep every join as flush as possible and tape if necessary.
- Do not count on the board for building regulation insulation. It is made for use over a substrate and is not designed to meet building regulation insulation requirements.
- Do not stand a point load on it before it is tiled. The board will compress or puncture under a low surface area impact, so protect it during the build.
How many boards to buy
Measure the floor, then divide the floor area by 0.72, the area of one board, and round up. Then add a few spare boards for cuts and offcuts, because the brick pattern wastes some board at the walls.
| Floor area | Boards needed | Tape at 2m a board |
|---|---|---|
| 3 square metres | 5 boards | 10m |
| 4 square metres | 6 boards | 12m |
| 6 square metres | 9 boards | 18m |
| 8 square metres | 12 boards | 24m |
A small ensuite of 4 square metres needs 6 boards, so one 10mm coated pack covers it exactly with no spare, and the 6mm coated pack of 8 gives two spare. A 6 square metre bathroom needs 9 boards, so a pack of 8 is one board short, and the pack of 20 uncoated boards suits a larger slab. Check the pack against the number, not only the area.
Choosing 6mm or 10mm
Choose 10mm when the heat loss matters most, such as on a cold concrete slab or a floor above an unheated space. Choose 6mm when the floor height is limited, such as where the new floor must meet an existing doorway. A 6mm board adds 6mm, a 10mm board adds 10mm, and the adhesive, the heating mat and the tile add their own thickness above that. Check the total build before you order the tiles.
Planning the job
Start with the substrate. Confirm what it is, and check it is stable and clean. Choose coated or uncoated on that basis. Then count the boards and the accessories. Plan the heating mat, the thermostat and the power position before the boards go down, because the cable runs and the sensor sit in the same floor. A licensed electrician should connect the heating. The controls are in controllers and thermostats and Thermogroup timers and thermostats, and the wider heating range is in bathroom heating and ventilation.
Before you order
Check the substrate: timber needs coated, and a wet room needs coated. Measure the floor and work out the board count from 0.72 square metres a board. Choose 6mm or 10mm to suit the floor height. Order reinforcing tape for the seams and fixing washers if the floor is timber. Confirm the heating mat is chosen, and make sure the boards are not laid over it.